Documentation

31.1 Quick start: a first power run

Quick start: a first power run

A power run needs a supported reference control stream, a design dataset, at least one scientific target when testing power, a method, and an output folder. Start with FIM because it validates the design quickly; add SSE only after the inputs and grid are correct.

What the controls mean

  • --method fim screens in seconds; sse re-estimates virtual trials; both writes comparable views.
  • The positional control stream is the simplest input. --ctl or [input] control_stream are equivalent fallbacks.
  • Use a new output directory. Existing non-empty folders are refused unless the run is resumed or overwrite is explicit.

The issued command is only the beginning of the audit trail. Always distinguish the reference model, the design template, the resolved scenario, the replicate-specific truth, the fitted result, and the test decision. A value can be correct at one layer and misinterpreted at another.

Command or settings pattern

nlmx power run101.ctl --method fim --sample-sizes 30,60,120 --test "CL~WT=0.75" -o power_fim

Command-line values override settings-file values. Use a fresh folder for an analytical run; preserve the command, resolved settings, log, checksums, and row-level data. Defaults are versioned behavior, so a production protocol should state important values explicitly.

Interpretation and quality control

Confirm the printed model, parameter source, design-subject count, scenario count, hypothesis, alpha, target, method, and seed before reading power.

For a novice review, first confirm counts and labels, then inspect numerical values, then ask whether the assumptions represent the proposed clinical study. For an expert review, additionally reconcile aggregates from row-level output, reproduce a subset of trials, and compare the implementation with an independent reference where the claim requires it.

Common mistakes

  • Launching 1,000 SSE replicates before a smoke run
  • Leaving the effect, null, or parameter scale implicit
  • Reporting a point estimate without its denominator, interval, method, and version

Minimum evidence to retain

  • nlmx version, command, .power file, resolved settings, seed, threads, and output checksums;
  • control stream, design dataset, EXT/COV or parameter sets, and their provenance;
  • scenario table, replicate rows and failures, method summaries, plots, report, and interpretation;
  • prespecified criteria, Monte Carlo target, validation scope, deviations, and reviewer decisions.

See the previous page, next page, and complete command and settings index.