Documentation

16.3 Dataset schema and event records

autoinit reads a headered comma-, tab-, or whitespace-delimited file. Rows beginning with # or @ are skipped. Column matching is case-insensitive, and mappings can be changed on the CLI or under [data].

Role Default Requirement
Subject ID Required.
Time TIME Required and numeric.
Concentration DV Required for observations.
Dose AMT Required; positive values can infer doses.
Event EVID Optional; inferred from AMT.
Missing DV MDV Optional; inferred from EVID.
Compartment CMT Optional, strongly useful for route.
Rate RATE Optional; identifies infusion.
Repeats ADDL, II Optional; expanded into doses.
Steady state SS Optional; identifies SS dosing.

Why full dosing history matters

NLS and ML simulate each subject's own doses and observation times. Incorrect ADDL/II, infusion RATE, SS, or dose time can therefore change the estimated typical parameters even if the concentration rows are intact. NCA chooses a specific interval, but the other methods use the full history.

Rows must be interpretable as dose or observation records. Explicit EVID/MDV reduces ambiguity. A positive concentration on an MDV=1 row is not automatically usable, and a blank DV on an observation row needs correct missingness coding.

Dataset scope

The command estimates one analyte and a linear PK structure at a time. Filter multiple DVID/analyte data to the intended endpoint. Parent–metabolite and PK/PD systems are not jointly modeled. Actual sampling times should be used when available; nominal times can distort absorption and terminal behavior.

Subject IDs are written to individual output. If sharing requires de-identification, create a controlled analysis ID before running and retain the key separately under governance.

Common mistakes

  • Assuming only the first dose matters to every method.
  • Leaving RATE in amount/minute while TIME is hours.
  • Mixing analytes in DV.
  • Expecting --keep-subject-ids to toggle autoinit hashing.

Checklist

  • Map every core/design column.
  • Reconstruct several subject timelines.
  • Verify ADDL/II/SS and infusion units.
  • Filter to one intended analyte.
  • Plan ID handling before creating outputs.

Further reading

Continue with filters and BLQ, route detection, and regimen pooling.