Documentation

11.17 Observations, BLQ, zero and negative values: OBS01–OBS05

OBS01 fails when no included observations exist. OBS02 warns about negative DV unless negative_ok=true; negatives can be valid for change-from-baseline PD endpoints but not ordinary concentrations.

OBS03 reviews zero DV. A true zero, predose value and below-quantification value are scientifically different. Set zero_ok=true only when zero is a valid measured endpoint, not as a global way to suppress BLQ warnings.

BLQ consistency

Configure a scalar LLOQ or row-specific LLOQ column and optionally a BLQ flag. OBS04 checks agreement among flag, LLOQ and imputation/exclusion behavior. OBS05 warns when the BLQ fraction exceeds the configured default 0.20.

There is no universally correct imputation. Likelihood-based M3/M4, exclusion, LLOQ/2 and other policies make different assumptions. qc-data checks consistency; the model and analysis plan determine the method.

Log DV

When dv_log=true, the scale expectation changes. Record whether DV stores natural concentration or log concentration. A log-transformed DV can be negative without representing a negative concentration.

A minimal BLQ decision table

For each observation, retain the measured/reported value, applicable LLOQ, BLQ flag, MDV and analysis DV. Review combinations such as DV < LLOQ, BLQ=0 or DV > LLOQ, BLQ=1. If the analysis uses an imputed DV, preserve the original result in a separate DROP column or upstream record so the transformation remains auditable. Count BLQ after filters by assay, time, dose and study—not only as one overall percentage.

Common mistakes

  • Treating every zero as a valid quantifiable measurement.
  • Comparing log DV directly with a natural-scale LLOQ.
  • Mixing LLOQ/2 and zero imputations within one dataset without reason.
  • Using MDV 1 for BLQ rows without documenting the analysis rule.

Checklist

  • Declare DV scale and units.
  • Configure LLOQ/BLQ fields and inspect consistency.
  • Quantify BLQ by time, dose, assay and group where relevant.
  • Align QC, model likelihood and reporting policy.

Further reading

See BLQ coding, command-specific BLQ behavior and BLQ case study.