Documentation

18.3 Structural model and prediction

The structural model maps dose events, time, covariates, fixed effects, and individual ETAs to a prediction. It may use an analytic ADVAN/TRANS solution, a numerical ODE system in $DES, or direct $PRED code. Estimation theory does not make a wrong structural model right; it only evaluates the likelihood implied by the supplied equations.

Write the prediction as \(Y_{ij}(\eta_i)=f(t_{ij};\theta,\eta_i,\text{history}_i)\). “History” includes all earlier doses, infusions, resets, steady-state instructions and time-varying covariates. The prediction evaluated with EPS equal to zero is the center of the observation model. PRED uses ETA zero; IPRED uses the conditional mode.

Parameterization affects numerical geometry. CL and V may be well scaled while rate constants are highly correlated, even if both parameterizations generate identical predictions. MU-referencing and log-normal random effects often make positivity and population interpretation natural. Scaling compartments and using consistent units can reduce extreme curvature differences.

For ODE models, solver tolerance becomes part of numerical accuracy. A noisy or insufficiently accurate solution can contaminate finite-difference population gradients. Analytic and ODE implementations of the same equations should be checked on identical events before comparing estimators.

Practical interpretation

For a first review, freeze THETA, OMEGA and SIGMA and calculate predictions for one uncomplicated subject in both implementations. Add one dose feature at a time—infusion, ADDL, lag, reset—until the full history is reproduced. This isolates structural translation from estimation. Only after fixed-parameter predictions agree should an OFV difference be attributed to the likelihood or optimizer. Record the maximum absolute and relative prediction differences at every step.

Common mistakes

Do not assume two control streams with similar parameter labels implement the same model. Dose compartment, bioavailability, scaling and event logic can change predictions. Avoid comparing optimizer behavior before confirming prediction equivalence at fixed parameters.

Checklist

  • Write the prediction equation and event dependence.
  • Verify units and compartment scaling.
  • Compare fixed-parameter predictions across implementations.
  • Identify positivity constraints and parameter correlations.
  • Set ODE tolerances below the intended estimation tolerance.

Further reading

See Chapters 8–9 for model execution and numerical foundations, then MU-referencing and cross-software alignment.