Documentation

28.27 AUCtau and CAVG

AUCtau and CAVG

AUCTAU integrates the selected profile over tau using linear, linear-log, or the default linear-up-log-down trapezoidal rule. CAVG is AUCTAU divided by tau. Full-interval coverage is essential: sampled/observed profiles that stop early are flagged and yield only the covered part rather than a silently extrapolated area.

Why this matters

This decision changes what population, random quantity, time interval, or numerical summary the command represents. For a novice, the safest habit is to write the question in one sentence before choosing an option, then verify that the resolved settings and output columns express that same question. For a reviewer, the important distinction is between what was assumed, what was randomly generated, what was calculated, and what can legitimately be concluded.

Detailed behavior

  • Dense profiles add regular grid points and avoid residual-error distortion.
  • Linear-up-log-down is often suitable for rising and exponential declining concentration profiles but remains a numerical rule.
  • At steady state for linear PK, dose/AUCTAU supports apparent clearance CLSS.
  • Compare integration rules when sparse terminal sampling materially affects AUC.

The subject-level table is the bridge between the design and the exposure result. Use it to check IDs, arms, population labels, age, sex, weight, dose, interval start, tau, ETA values, and added covariates. Use the metric table to check one row per subject and simulation, the requested metric columns, and COVERED. Use pooled and replicate summaries for different purposes: pooled rows describe all simulated subject outcomes, while replicate intervals describe how a finite simulated study result varies from study to study.

Example command or settings fragment

nlmx sims run.ctl --metrics AUCTAU,CAVG --auc-method linear-up-log-down --grid-points 241

Start with a small smoke run and inspect the transcript before scaling. For command-line work, quote expressions containing comparison signs, brackets, or commas as required by the shell. For a permanent analysis, prefer a settings file: it exposes settings-only controls, resolves paths relative to itself, rejects unknown keys, and is echoed in fully resolved form with the output.

Interpretation and quality control

Check units: concentration × time for AUC and concentration for CAVG. Report tau and integration rule, and exclude or qualify intervals with COVERED=0 in decision summaries.

At minimum, reconcile the console summary with the CSV/JSON result, inspect warnings and notes, confirm subject and observation counts, verify requested groups and targets, and review the source model's applicability. A chart can reveal shape and subgroup patterns, but every reported number should come from the tables. If a result changes a decision, run a prespecified sensitivity for Monte Carlo stability, parameter uncertainty, population assumptions, and the metric-profile source.

Common mistakes

  • Omitting AUC units
  • Interpreting partial coverage as AUCTAU
  • Changing integration rule between dose scenarios

Also avoid overwriting a completed evidence folder merely to change styling. Create a new scenario directory or preserve the prior checksums so analytical changes remain distinguishable from presentation changes.

What to retain and report

  • the nlmx version, complete issued command, submitted settings, and resolved _settings.sims;
  • CTL, selected EXT, optional COV or parameter table, and supplied dataset or population-generation assumptions;
  • seed, subproblems, thread count, ETA/EPS and parameter-uncertainty policy;
  • metric interval, tau, profile source, grid, integration rule, group definitions, and target limits;
  • numerical tables, JSON, HTML, figures, transcript, checksums, warnings, sensitivities, and scoped interpretation.

See the previous page, next page, and complete sims command and settings index.