30.17 Information from the mean and covariance
nlmx approximates each subject’s observation vector as multivariate normal with mean mu and covariance V. For parameters p and q, information is dmu/dp transpose V-inverse dmu/dq plus one half the trace of V-inverse dV/dp V-inverse dV/dq. The first term measures how parameters move the expected profile; the second measures how they change observation covariance.
Concepts to keep separate
- V includes random-effect propagation H Omega H-transpose and residual variance, so observations within a subject are correlated.
- The mean derivative is discounted by V-inverse: a visible prediction shift counts less when noise is high or redundant.
- The trace term can inform variance parameters and, in a full FIM, fixed effects that also change V.
- Subject information matrices are later summed according to the population design.
Terminology matters because a single scenario can contain several denominators and several sources of randomness. Truth is the parameter vector used to generate a replicate. Estimate is the value recovered from that replicate. Design is the planned arrangement of subjects, arms, doses, and observations. Method is the approximation or simulation–estimation procedure used to predict performance. A credible report labels all four.
Mathematical or operational walkthrough
For one independent observation with constant variance sigma-squared, the trace term for a mean-only parameter is zero and information reduces to (dmu/dp)^2/sigma^2. The population mixed-effects expression is the multivariate generalisation.
For novices, read every expression from the inside out: identify the scientific effect, identify the null value, put both on the same parameter scale, identify the variance or information that belongs to the actual design, and only then calculate a test statistic or sample size. Units and parameterisation should cancel in a way that leaves a dimensionless statistic.
How this maps to nlmx
Check units: the information for a clearance parameter has inverse-clearance-squared units, while cross-terms mix units. Standardised correlations after inversion are easier to compare across parameters.
Chapter 30 explains the statistical and implementation concepts. Chapter 31 gives the complete nlmx power command, every CLI and settings control, precedence, output schema, and production workflow. This separation is deliberate: choosing an option correctly requires understanding which estimand and assumption it changes.
Quality-control checklist
- Is V positive definite for each subject design?
- Are within-subject correlations represented?
- Are derivatives on the fitted parameter scale?
- Is the reduced/full trace-term choice documented?
The graph is explanatory; the CSV, JSON, resolved settings, model inputs, and replicate rows are the authoritative evidence. When a plotted point looks surprising, diagnose the underlying rows before changing the design.
Common mistakes
- Treating repeated samples as independent
- Omitting the residual-variance component
- Comparing raw information across parameters with different units
Also avoid copying a sample size from a nearby project. Power is conditional on the model, tested effect, covariate distribution, schedule, residual and random variability, attrition, test, estimator, and success criteria. Similar-looking studies can have very different information.
Evidence to retain
- scientific question, estimand, hypothesis, alpha, target, and criteria;
- model/data/design inputs, parameter source and uncertainty distribution;
- software version, method, approximation, seed, threads, command, and resolved settings;
- scenario grid, row-level results, failures, denominators, intervals, diagnostics, and checksums;
- scripts that calculate derived tables and figures, plus the interpretation and limitations.
Navigation
See the previous page, next page, and formula and decision index.