27.14 Simulated-percentile confidence intervals
Within each bin, every replicate yields one value for each requested percentile. Across replicates, nlmx reports the median simulated percentile and the requested confidence interval, default 95%. The plot band is this interval, with a dashed line for the simulated median percentile.
Novice translation
This topic changes three practical decisions in a predictive-check review. First, the interval reflects simulated-study variation conditional on the selected parameter policy and design. Second, it is not a confidence interval for THETA and not an individual prediction interval. Third, lower CI levels create narrower bands and more outside flags; report --ci whenever comparing results. Keep those decisions separate: one defines what is simulated or summarised, another controls how evidence is displayed, and the last controls what conclusion the evidence can support. A reviewer should be able to reproduce each decision from the resolved settings and numerical tables, not infer it from the appearance of the figure.
What to understand
- The interval reflects simulated-study variation conditional on the selected parameter policy and design.
- It is not a confidence interval for THETA and not an individual prediction interval.
- Lower CI levels create narrower bands and more outside flags; report
--ciwhenever comparing results.
Practical interpretation
Increase replicates when band limits or outside flags move materially across seeds, particularly for extreme percentiles and small strata.
Evidence to retain
For simulated-percentile confidence intervals, retain the issued command, vpc_settings.vpc, the source model/data/result identifiers, seed and replicate count, the relevant CSV/JSON fields, warnings and notes, and the exact figure used for interpretation. Record any sensitivity run that changed the conclusion. If an option was selected after seeing the data, label that analysis exploratory. This evidence separates a reproducible diagnostic decision from a visual impression and lets another pharmacometrician check counts, transformations, exclusions, and uncertainty assumptions.
Common mistakes
- Calling the band parameter uncertainty by default
- Comparing runs with different CI levels
- Ignoring Monte Carlo uncertainty
Page checklist
- Record CI level
- State uncertainty sources
- Assess stability
- Interpret band and dashed center
Further reading
See previous page, next page, complete VPC command and settings index.