Documentation

17.6 One-, two-, and three-compartment models

A one-compartment model assumes instantaneous distribution within one apparent space. After an IV bolus its concentration declines monoexponentially; with first-order oral input, absorption and elimination shape the profile. It is parsimonious and often adequate when sampling does not resolve distribution.

A two-compartment model adds a peripheral space and intercompartmental clearance. Typical parameters are CL, central volume V2, Q, and peripheral volume V3. It can represent a rapid distribution phase followed by slower terminal decline. A three-compartment model adds another Q/volume pair and requires particularly informative early and late sampling.

Compartment count is not the number of visible bends in a noisy mean curve. Population variability, absorption, censoring and sampling can mimic phases. More compartments add parameters, correlations, flat likelihood directions and condition-number problems. Physiological plausibility of volumes and clearances matters alongside criterion improvement.

The candidates use compatible parameterizations where possible and inherit parent estimates. Check the generated ADVAN/TRANS or differential-equation representation in model_comparison.csv and best_model.ctl. Apparent oral parameters include bioavailability unless absolute F is supported.

In the frozen oral example, OFV improves dramatically from one to two compartments and again to three. BICc recommends 3cmt_abs, but both larger candidates are ill-conditioned, with the three-compartment condition number especially large. That is a caution requiring sensitivity and diagnostic review, not a reason to erase the candidate.

Common mistakes

Do not select three compartments because its OFV is lowest, interpret a peripheral volume as a literal organ volume, or accept implausible exchange clearances without checking units. Sparse late sampling can make terminal parameters unstable even when convergence is reported.

Checklist

  • Ensure the design observes expected distribution and terminal phases.
  • Compare parameter plausibility, RSE, correlations and conditioning.
  • Inspect residual patterns for systematic phase misspecification.
  • Perform sensitivity fits when a complex model is fragile.
  • Prefer parsimony when evidence is practically indistinguishable.

Further reading

Work through the oral distribution example and then condition-number interpretation.