15.7 Analysis intervals, steady state, tau, and duplicates

The [analysis] section controls which constructed profiles are retained and how ambiguous timing records are resolved. These choices occur before parameter interpretation and can change both the number of rows and the values in them.

Interval and steady-state controls

intervals = "all" is the default; alternatives are first and last. The CLI equivalent is --nca-intervals. steady_state = "auto" uses an SS record with II. none, last, or all provide explicit alternatives via file or --steady-state.

tau supplies a dosing interval when the data do not. Prefer observed design variables when reliable. A manually supplied tau affects AUCtau, Cavg, Ctau, fluctuation, steady-state clearance, and accumulation summaries, so record its origin.

Sample and time limits

min_observations = 3 is the default. A profile with fewer usable observations is retained with a SKIPPED reason and no invented parameters. Raising the threshold can improve coverage quality but reduces the endpoint population. The configuration-only max_time excludes observations later than that postdose time; use it to implement a prespecified window, not to conceal an inconvenient terminal sample.

Duplicate times

Several samples at one postdose time are resolved by:

  • mean (default),
  • first,
  • last,
  • max, or
  • error.

“First” and “last” depend on input row order, making them harder to reproduce after sorting. Mean is neutral for replicate measurements but may be inappropriate when duplicates represent different analytes or accidental merged records. error is the safest QC choice when duplicates should never occur.

Duplicate handling changes Tmax, Cmax, local AUC, and terminal eligibility. Reconcile duplicate records at the source or document why aggregation is scientifically valid.

Common mistakes

  • Equating the last interval with demonstrated steady state.
  • Supplying tau in days while TIME is hours.
  • Dropping skipped profiles from denominators without reporting.
  • Using first after an uncontrolled spreadsheet sort.

Checklist

  • State interval and steady-state selection separately.
  • Verify tau against II and protocol.
  • Report the minimum observation threshold.
  • List and review duplicate times before aggregation.
  • Confirm max_time does not truncate required terminal evidence.

Further reading