Documentation

31.40 Worked THETA test with a nonzero null

Worked THETA test with a nonzero null

The executed run generated THETA(3)=1.4 and fixed the reduced model at 1.1. At N=40 and 80, all eight smoke replicates rejected by the primary test; reduced FIM estimated target N=12.

What the controls mean

  • The comparison is 1.4 versus 1.1, not versus zero.
  • Eight replicates give a 0.676–1.000 Wilson interval even when all reject.
  • The smallest tested SSE N=40 cannot locate a target near 12.

The issued command is only the beginning of the audit trail. Always distinguish the reference model, the design template, the resolved scenario, the replicate-specific truth, the fitted result, and the test decision. A value can be correct at one layer and misinterpreted at another.

Command or settings pattern

--test "THETA(3)=1.4;null=1.1;name=KA above 1.1"

Command-line values override settings-file values. Use a fresh folder for an analytical run; preserve the command, resolved settings, log, checksums, and row-level data. Defaults are versioned behavior, so a production protocol should state important values explicitly.

Interpretation and quality control

Add smaller N values and many more replicates if estimating this target; check whether KA=1.1 is scientifically meaningful.

For a novice review, first confirm counts and labels, then inspect numerical values, then ask whether the assumptions represent the proposed clinical study. For an expert review, additionally reconcile aggregates from row-level output, reproduce a subset of trials, and compare the implementation with an independent reference where the claim requires it.

Common mistakes

  • Calling N=40 the minimum
  • Forgetting THETA units and bounds
  • Reporting a point estimate without its denominator, interval, method, and version

Minimum evidence to retain

  • nlmx version, command, .power file, resolved settings, seed, threads, and output checksums;
  • control stream, design dataset, EXT/COV or parameter sets, and their provenance;
  • scenario table, replicate rows and failures, method summaries, plots, report, and interpretation;
  • prespecified criteria, Monte Carlo target, validation scope, deviations, and reviewer decisions.

See the previous page, next page, and complete command and settings index.