Documentation

41.8 Case 2: is exposure proportional to dose?

Dose proportionality as a power model

What you will learn

  • Fit and read a power model P = a · dose^b for exposure against dose.
  • Derive the acceptance band for b from the dose range, and see why a wider range gives a narrower band.
  • Conclude "proportional" only when the whole interval for b lies inside the band.
  • Recognise what the conclusion does and does not say about the data in the middle.

Prerequisites: 41.6 and Chapter 15.

The question: if the dose is doubled, is exposure doubled?

The evidence: the Chapter 15 bundle dose_proportionality: 12 subjects, four at each of 50, 100 and 200 mg, orally, ten samples each; settings [dose_proportionality] enabled = true; output nca_dose_proportionality.csv.

The model

The dose-proportionality analysis regresses the logarithm of an exposure measure on the logarithm of the dose:

ln P = ln a + b · ln(dose)

so that P = a · dose^b. The exponent b is the whole story: b = 1 means doubling the dose doubles exposure (proportional); b > 1 means exposure rises faster than dose (more than proportional, typical of saturable clearance); b < 1 means exposure rises more slowly (less than proportional, typical of saturable absorption or solubility). Three parameters are analysed: CMAX, AUCLAST and AUCINF_OBS.

The numbers

parameter   stratum                      n levels      b          CI       criterion   conclusion
CMAX        extravascular, single dose  12      3      1   0.909 – 1.091   0.839 – 1.161  proportional
AUCLAST     extravascular, single dose  12      3      1   0.909 – 1.091   0.839 – 1.161  proportional
AUCINF_OBS  extravascular, single dose  12      3      1   0.909 – 1.091   0.839 – 1.161  proportional

The csv carries more digits: b = 1.0000000000 (all three), standard error 0.0502, R² 0.9754. Dose-normalised exposure is constant: the mean CMAX at 50, 100 and 200 mg is 0.807, 1.613 and 3.226 mg/L, a ratio of 2.00 between each pair of levels.

Where the criterion band comes from

The "criterion" column is the interval of b that would count as proportional, and it is computed from the dose range, not chosen. The usual rule says exposure is proportional if a dose ratio of r changes exposure by a factor between 0.8 and 1.25. For r = 200 / 50 = 4:

lower = 1 + ln(0.8) / ln(4) = 1 − 0.2231 / 1.3863 = 0.839

upper = 1 + ln(1.25) / ln(4) = 1 + 0.2231 / 1.3863 = 1.161

These are exactly the printed numbers. The design lesson follows at once: the wider the dose range, the narrower the band. With a dose ratio of 2 the band would be 1 ± 0.322; with a ratio of 8, 1 ± 0.107. A study that wants to show proportionality across a narrow range gets a wide, forgiving band; one across a wide range must have a much more precise b.

The decision rule

The interval for b is 0.909 – 1.091. Its half-width, 0.0910, equals 1.812 × 0.0502, which is the t-quantile with 10 degrees of freedom for a two-sided 90 % interval times the standard error, so this is a 90 % interval. It lies entirely inside the band (0.839 – 1.161), so the conclusion is proportional. Three outcomes are possible:

The interval for b is… Conclusion
inside the band proportional
outside the band on one side, not touching it more / less than proportional
straddling a boundary inconclusive: the data neither support nor reject proportionality

The third outcome is the common real-world one and the one analysts most often misreport. A confidence interval that overlaps the boundary does not mean "non-proportional". It means the study is too small or too noisy to decide, a statement about the study.

(Hypothetical, to show the geometry: with the same standard error, an exponent of 1.30 would give an interval of 1.21 – 1.39, entirely above 1.161, hence "more than proportional"; an exponent of 1.15 would give 1.06 – 1.24, which straddles the upper boundary and is inconclusive. Neither is a result of this bundle.)

Reading the figure

The twelve points lie on a straight line of slope 1 on the log–log plot. The scatter at each dose level is the between-subject variability of exposure (CV 10.3 % at the 50 mg level, from the summary), which is what gives the standard error of 0.0502. A smaller scatter, or more subjects per level, would narrow the interval. The straightness hides one thing the model cannot show: with three dose levels the power model cannot distinguish a smooth power curve from a curve that is proportional at 50 and 100 mg and bends at 200 mg. Adding a level in the middle, or at the top, would answer that.

The decision

Question Evidence Decision Reversible?
Is exposure dose-proportional over 50–200 mg? nca_dose_proportionality.csv: b = 1.000, interval 0.909–1.091 inside 0.839–1.161 Yes over the studied range; dose scaling by multiplication is supported for CMAX, AUCLAST and AUCINF yes

What would have changed it: an interval touching either boundary.

What this case does not show

The conclusion is local: it applies between 50 and 200 mg only. Extrapolating to 400 mg because the line is straight is an assumption, and for drugs with saturable processes it is exactly the assumption that fails.

Review checklist

  • Is the criterion band computed from your dose ratio?
  • Is the whole interval for b inside the band, or only the point estimate?
  • Is an inconclusive result reported as inconclusive?
  • Do you state the dose range over which the conclusion holds?

See the previous page, the next page and the complete case-study reference.