11.31 Case study 4: BLQ, outliers and sampling

Subject 3 in the defective fixture has DV 0 at TIME 0 and DV 0.05 at TIME 4. The configured LLOQ is 0.1, but BLQ is 0 on both rows. OBS03 warns about the unexplained zero, OBS04 about BLQ/LLOQ inconsistency, and OBS05 about the overall BLQ fraction under the configured definition.

Subject 1 also has DV 99 after values 8 and 3.5. Whether it is detected by an automated outlier rule depends on bin sizes and comparison data; a small fixture may not meet the minimum eight observations per bin. Absence of OBS06 does not certify 99.

Generated concentration-time profiles for the defective fixture

Figure 11.15. The actual qc-data profile plot makes the unusual values and sparse comparison context visible; the source rows and assay evidence still determine disposition.

Corrective reasoning

Verify the assay result, LLOQ applicable to each record and BLQ coding convention. Decide whether DV retains the reported numeric result, an imputed value, or is excluded according to the analysis plan. Ensure QC and likelihood use the same convention.

For 99, check units, decimal placement, sample identity, dilution/reanalysis and collection time. Retain a confirmed unusual value and document it; exclusion requires a defensible rule.

Sampling context

Sparse time bins weaken population outlier detection. Inspect concentration-time and swimmer plots, source rows and protocol schedule. Automated thresholds should be supplemented—not made more aggressive until something fires.

Expected rerun evidence

After correcting flags from assay evidence, OBS04 should PASS and OBS05 should report the revised fraction. OBS03 may remain if a genuine zero is neither BLQ nor allowed by configuration; resolve its meaning separately. A confirmed DV 99 can remain and may continue to warn. The disposition should say why it was retained and which sensitivity analyses, if any, will evaluate its influence.

Common mistakes

  • Setting BLQ=1 solely because DV is low without checking assay LLOQ.
  • Replacing every BLQ with zero.
  • Deleting DV 99 because it “looks wrong.”
  • Interpreting no outlier warning as proof of plausibility.

Checklist

  • Verify assay-specific LLOQ and flags.
  • Align BLQ representation with analysis method.
  • Source-check unusual values and times.
  • Review automatic-rule applicability/sample size.

Further reading

See BLQ checks, outlier checks and diagnostic plots.