32.7 Continuous endpoints: the Emax model

The Emax model is E0+Emax·C/(EC50+C). Emax is the asymptotic maximum drug-related change, and EC50 is exposure producing half of Emax. The curve is mechanistically interpretable but only when the exposure range identifies both its early rise and approach to plateau.
Core concepts
- Emax may be positive or negative depending on endpoint direction; EC50 is constrained positive and estimated on a log scale.
- If EC50 lies below the lowest active exposure, the observed active range is almost flat; if above the maximum, Emax is extrapolated.
- E0, Emax, and EC50 can be strongly correlated without placebo or broad exposure coverage.
Keep five layers separate: the dose assignment, the individual exposure, the endpoint definition, the statistical estimand, and the clinical decision. A fitted curve connects exposure and endpoint within the analysed data; it does not automatically identify the effect of changing dose or exposure in another population.
Worked interpretation
The unadjusted executed fit selected Emax, but EC50=7.98 was below the lowest active exposure and had 91.5% RSE. The fit described association but did not precisely locate the half-maximal region.
Reading all three parameters together
At C=0, the predicted mean is E0. At C=EC50, the drug-related component is Emax/2. At C=3×EC50, it is 75% of Emax; at 9×EC50, 90%. These landmarks help reviewers see whether the observed range contains the rising and plateau regions. Emax is an asymptote, not the response at the largest observed exposure.
For a contrast from C1 to C2, subtract the two predictions; do not interpret Emax itself unless the plateau is supported. When every active exposure is much larger than EC50, active predictions are nearly flat and Emax/EC50 combinations may trade off. When every exposure is much smaller, the model behaves approximately linearly with slope Emax/EC50, so neither parameter is separately learned well.
Review the EC50 confidence interval against the active exposure distribution, the Emax–EC50 correlation, profile likelihood, starting-value sensitivity, and curve bands. The executed EC50 of 7.98 sits below the active range and has 91.5% RSE: the observed active plateau is plausible, but the precise half-maximal location is not.
For a novice, translate every coefficient back to the endpoint scale. Name the starting exposure, ending exposure, predicted outcome at both, contrast, interval, and observed support. For categorical or survival endpoints, also show absolute probabilities or survival estimates because odds and hazard ratios can be hard to interpret clinically.
Quality control and scientific review
Report the observed range, EC50 interval, percent Emax reached at doses, parameter correlation, and plausible extrapolation.
Review sample size alone only after checking events, category cells, visit counts, placebo support, exposure overlap, exclusions, and missingness. A statistically precise curve can still be clinically irrelevant, confounded, extrapolated, or based on an endpoint definition that does not match the intended estimand.
Common mistakes
- Interpreting Emax as the largest observed response
- Calling EC50 a dose
- Treating a significant exposure term as proof that the selected shape or causal story is correct
Evidence to retain
- exposure definition, window, units, derivation, estimation uncertainty, and distribution by arm;
- endpoint derivation, time origin/visit, analysis population, missing/censoring rules, and exclusions;
- candidate models, covariate rationale, contrasts, selection criterion, diagnostics, failed/unstable fits;
- effect estimates with intervals, observed range, sensitivity analyses, software version, settings, and checksums.
Navigation
See the previous page, next page, and model and estimand catalogue.