Documentation

33.3 Exposure, response, type, and the analysis grid

Exposure, response, type, and the analysis grid

Every response × exposure combination becomes a separate analysis. type selects the likelihood and allowable model set: continuous, binary, ordinal, count, TTE, or longitudinal. Multiple metrics are useful only when their units, derivations, windows, and missingness are qualified.

Command or configuration pattern

nlmx er er.csv --er-type continuous --exposure AUC,CMAX --response CHG12,BIOMARKER ...

The relevant controls are: type; exposure; response; models; name; --er-type; --exposure; --response; --models. Use the complete command and settings index for accepted values, defaults, CLI mappings, and settings-only controls.

A reliable operating sequence

  1. State the endpoint estimand, exposure metric/window/units, analysis population, adjustment set, and clinically useful contrast.
  2. Reconcile input rows, subjects, arms, exposure availability, endpoint information, and all endpoint-specific fields.
  3. Run the smallest useful specification first; inspect exclusions and eligible models before adding subgroups, selection, or bootstrap.
  4. Read absolute predictions and observed support alongside relative effects, information criteria, p-values, and diagnostics.
  5. Archive the command, .er file, mutated/used data, exclusions, transcript, tables, plots, report, version, and checksums.

How to read and review the result

Predict the grid size before running. Four exposures and three responses create twelve analyses before by subgroups. Compare fit criteria only for the same endpoint and analysed subjects. A metric fitted to more complete rows has a different evidence base.

For a novice, the safest reading order is er_summary.txt → er_analyses.csv → the analysis-specific exclusions and model table → effects/predictions → diagnostic plots → row-level data → report.html. The report is a presentation layer; the CSV/JSON files and transcript are the audit layer.

Quality-control questions

  • Did the number of analysed subjects, events, categories, exposure groups, and visits match the specification?
  • Were placebo, active zeros, missing values, filters, repeated rows, categories, offsets, censoring, and covariate references handled as intended?
  • Were ineligible fits retained and explained rather than silently dropped or allowed to win?
  • Does the reported contrast stay inside exposure support, and are its units and endpoint direction clear?
  • Do diagnostics and sensitivities support the same decision, and are causal and transportability limits explicit?

Common failure modes

  • Treating the best criterion or smallest p-value as a clinical conclusion.
  • Reading an odds, rate, or hazard ratio without its exposure contrast and absolute outcome context.
  • Overwriting an evidence directory before preserving the prior settings, log, and checksums.

See the previous page, next page, and complete command and settings index.