28.13 Fixed and weight-based dosing
A fixed regimen uses --dose; a weight-based regimen uses --dose-per-kg. The latter multiplies the rounded generated weight, then applies optional minimum, maximum, and dose-rounding rules. Because model allometry and clinical dose scaling need not have identical exponents, weight-based dosing does not necessarily equalise exposure.
Why this matters
This decision changes what population, random quantity, time interval, or numerical summary the command represents. For a novice, the safest habit is to write the question in one sentence before choosing an option, then verify that the resolved settings and output columns express that same question. For a reviewer, the important distinction is between what was assumed, what was randomly generated, what was calculated, and what can legitimately be concluded.
Detailed behavior
--doseand--dose-per-kgare mutually exclusive.- Dose is written to AMT and to the subject table; a DOSE input item receives the subject dose on every record.
- Rounding order matters near limits and presentation strengths.
- Compare raw mg/kg intent, final administered dose, and resulting exposure across weight.
The subject-level table is the bridge between the design and the exposure result. Use it to check IDs, arms, population labels, age, sex, weight, dose, interval start, tau, ETA values, and added covariates. Use the metric table to check one row per subject and simulation, the requested metric columns, and COVERED. Use pooled and replicate summaries for different purposes: pooled rows describe all simulated subject outcomes, while replicate intervals describe how a finite simulated study result varies from study to study.
Example command or settings fragment
nlmx sims run.ctl --dose-per-kg 2 --dose-min 10 --dose-max 150 --dose-round 5 --scatter WT:AUCTAU
Start with a small smoke run and inspect the transcript before scaling. For command-line work, quote expressions containing comparison signs, brackets, or commas as required by the shell. For a permanent analysis, prefer a settings file: it exposes settings-only controls, resolves paths relative to itself, rejects unknown keys, and is echoed in fully resolved form with the output.
Interpretation and quality control
Report dose units, order of caps/rounding, and realised dose distribution. A flat exposure–weight smoother can support—but does not alone prove—adequate weight-based dosing because other correlated covariates may drive residual trends.
At minimum, reconcile the console summary with the CSV/JSON result, inspect warnings and notes, confirm subject and observation counts, verify requested groups and targets, and review the source model's applicability. A chart can reveal shape and subgroup patterns, but every reported number should come from the tables. If a result changes a decision, run a prespecified sensitivity for Monte Carlo stability, parameter uncertainty, population assumptions, and the metric-profile source.
Common mistakes
- Assuming mg/kg removes all size effects
- Reporting nominal rather than administered dose
- Ignoring formulation or tablet-strength constraints
Also avoid overwriting a completed evidence folder merely to change styling. Create a new scenario directory or preserve the prior checksums so analytical changes remain distinguishable from presentation changes.
What to retain and report
- the nlmx version, complete issued command, submitted settings, and resolved
_settings.sims; - CTL, selected EXT, optional COV or parameter table, and supplied dataset or population-generation assumptions;
- seed, subproblems, thread count, ETA/EPS and parameter-uncertainty policy;
- metric interval, tau, profile source, grid, integration rule, group definitions, and target limits;
- numerical tables, JSON, HTML, figures, transcript, checksums, warnings, sensitivities, and scoped interpretation.
Navigation
See the previous page, next page, and complete sims command and settings index.