31.15 Power-form continuous covariates
For form power, the parameter factor is (X/reference)^beta; nlmx uses log(X/reference) as the design column. Every covariate value and the reference must be positive. Reference defaults to the subject-level median.
What the controls mean
- beta=0 gives factor one; beta=0.75 is an exponent, not a 75% shift.
- A reference near the population centre reduces intercept/effect correlation.
- Time-varying covariates can use per-record values.
The issued command is only the beginning of the audit trail. Always distinguish the reference model, the design template, the resolved scenario, the replicate-specific truth, the fitted result, and the test decision. A value can be correct at one layer and misinterpreted at another.
Command or settings pattern
--test "CL~WT=0.75;form=power;ref=70"
Command-line values override settings-file values. Use a fresh folder for an analytical run; preserve the command, resolved settings, log, checksums, and row-level data. Defaults are versioned behavior, so a production protocol should state important values explicitly.
Interpretation and quality control
Calculate factors at clinically meaningful low and high X values and verify units cancel in X/reference.
For a novice review, first confirm counts and labels, then inspect numerical values, then ask whether the assumptions represent the proposed clinical study. For an expert review, additionally reconcile aggregates from row-level output, reproduce a subset of trials, and compare the implementation with an independent reference where the claim requires it.
Common mistakes
- Using a power form with zero values
- Interpreting beta as percent change
- Reporting a point estimate without its denominator, interval, method, and version
Minimum evidence to retain
- nlmx version, command,
.powerfile, resolved settings, seed, threads, and output checksums; - control stream, design dataset, EXT/COV or parameter sets, and their provenance;
- scenario table, replicate rows and failures, method summaries, plots, report, and interpretation;
- prespecified criteria, Monte Carlo target, validation scope, deviations, and reviewer decisions.
Navigation
See the previous page, next page, and complete command and settings index.