A.15 Non-compartmental analysis: the formulas, derived and checked
What you will learn
- Derive the linear and logarithmic trapezoid rules, and the first-moment (AUMC) segments, and apply the three rules (linear, linear–log, linear-up/log-down).
- Fit the terminal slope \(\lambda_z\) by weighted regression, apply the best-fit window rule, and compute \(t_{1/2}\), adjusted \(R^2\) and span.
- Compute \(\mathrm{AUC}_\infty\), the extrapolated fraction, MRT, CL/F and \(V_z\)/F; check dose proportionality and a geometric-mean ratio.
Prerequisites: A.5 and Chapter 14.
Areas under the curve
A profile is a set of points \((t_k,C_k)\). The area over one segment \([t_1,t_2]\), \(\Delta t=t_2-t_1\), depends on how the concentration is assumed to behave between the points.
Linear trapezoid — the concentration is a straight line:
Logarithmic trapezoid — the concentration is an exponential, \(C(t)=C_1e^{-k(t-t_1)}\) with \(k=\ln(C_1/C_2)/\Delta t\). Integrating,
It is exact for a mono-exponential decline and needs both concentrations positive and different. A declining profile is nearly exponential, so the logarithmic rule is more accurate on the way down, where the linear rule overestimates (a chord lies above a convex curve); on the way up, the linear rule is the sensible choice.
Rule (auc_method) |
Segments that use the logarithmic form |
|---|---|
linear |
none |
linear-log |
all segments starting at or after \(T_{\max}\) |
linear-up-log-down (default) |
segments with \(C_2<C_1\) (falling) |
First-moment area. \(\mathrm{AUMC}=\int tC\,dt\) is the area under \(t\,C(t)\), and gives the mean residence time. Per segment:
with \((e^L-1-L)/L^2\to\tfrac12\) as \(L\to0\) (a series is used for \(\lvert L\rvert<0.1\), and the log ratio is computed from the relative difference to keep digits when concentrations are almost equal).
The terminal slope
After \(T_{\max}\) the profile declines as \(C\approx Ae^{-\lambda_zt}\), so \(\ln C\) is linear in \(t\) with slope \(-\lambda_z\). Regress \(\ln C\) on \(t\) with weights \(w\) (\(1\) for uniform, \(1/C\), or \(1/C^2\)):
The best-fit window. Every window of the last \(n=n_{\min},\dots,n_{\max}\) points (\(n_{\min}=3\)) is regressed. Among the windows with \(\lambda_z>0\), the winners are those whose \(R^2_{\text{adj}}\) is within tolerance (\(10^{-4}\)) of the best, and the one with the most points is chosen. The fit is rejected when \(R^2_{\text{adj}}<\) min_adj_r2 (0.7), flagged when the span is below 2 half-lives, and flagged when fewer than 3 points are used.
Derived parameters
With dose \(D\), last measurable sample \((t_{\text{last}},C_{\text{last}})\), and \(\hat C_{\text{last}}=e^{a-\lambda_zt_{\text{last}}}\) the regression value:
| Parameter | Formula |
|---|---|
| \(\mathrm{AUC}_\infty\) (observed) | \(\mathrm{AUC}_{\text{last}}+C_{\text{last}}/\lambda_z\) |
| \(\mathrm{AUC}_\infty\) (predicted) | \(\mathrm{AUC}_{\text{last}}+\hat C_{\text{last}}/\lambda_z\) |
| % extrapolated | \(100\,(\mathrm{AUC}_\infty-\mathrm{AUC}_{\text{last}})/\mathrm{AUC}_\infty\) |
| \(\mathrm{AUMC}_\infty\) | \(\mathrm{AUMC}_{\text{last}}+t_{\text{last}}C^\ast/\lambda_z+C^\ast/\lambda_z^2\), \(C^\ast=C_{\text{last}}\) or \(\hat C_{\text{last}}\) |
| MRT | \(\mathrm{AUMC}_\infty/\mathrm{AUC}_\infty\) (minus \(t_{\text{inf}}/2\) for an infusion) |
| CL (IV), CL/F (extravascular) | \(D/\mathrm{AUC}_\infty\) |
| \(V_z\), \(V_z\)/F | \(D/(\lambda_z\,\mathrm{AUC}_\infty)\) |
| \(V_{ss}\) (IV) | \(\mathrm{CL}\cdot\mathrm{MRT}\) |
| at steady state | \(\mathrm{AUC}_\tau\), \(C_{\text{avg}}=\mathrm{AUC}_\tau/\tau\), fluctuation \(100(C_{\max}-C_{\min})/C_{\text{avg}}\), \(\mathrm{CL}_{ss}=D/\mathrm{AUC}_\tau\) |
| predicted accumulation | \(1/(1-e^{-\lambda_z\tau})\) |
The tail formulas follow from integrating the terminal exponential: \(\int_{t_{\text{last}}}^{\infty}C_{\text{last}}e^{-\lambda_z(s-t_{\text{last}})}ds=C_{\text{last}}/\lambda_z\), and \(\int_{t_{\text{last}}}^\infty s\,C(s)\,ds=t_{\text{last}}C_{\text{last}}/\lambda_z+C_{\text{last}}/\lambda_z^2\).
A worked illustration
An oral profile after a 100 mg dose (invented numbers to show the arithmetic; concentrations in mg/L, time in h):
| \(t\) | 0 | 0.5 | 1 | 2 | 4 | 8 | 12 | 24 |
|---|---|---|---|---|---|---|---|---|
| \(C\) | 0 | 3.1 | 5.4 | 6.8 | 5.5 | 3.3 | 2.0 | 0.45 |
\(C_{\max}=6.8\) at \(T_{\max}=2\) h. The segments, with the default rule (logarithmic only where the profile falls):
| Segment | \(C_1\to C_2\) | linear AUC | rule AUC | AUMC segment |
|---|---|---|---|---|
| 0–0.5 | 0 → 3.1 | 0.775 | 0.775 | 0.3875 |
| 0.5–1 | 3.1 → 5.4 | 2.125 | 2.125 | 1.7375 |
| 1–2 | 5.4 → 6.8 | 6.100 | 6.100 | 9.5000 |
| 2–4 | 6.8 → 5.5 | 12.300 | 12.254 | 36.3292 |
| 4–8 | 5.5 → 3.3 | 17.600 | 17.227 | 100.4414 |
| 8–12 | 3.3 → 2.0 | 10.600 | 10.384 | 102.1129 |
| 12–24 | 2.0 → 0.45 | 14.700 | 12.469 | 206.5038 |
| sum | 64.200 | 61.334 | 457.012 |
By hand, the 2–4 h falling segment: \((6.8-5.5)\times2/\ln(6.8/5.5)=2.6/0.21217=12.254\); the linear rule gives \(12.300\). The AUMC of the same segment: \(t_1\mathrm{AUC}_{12}=2\times12.254=24.508\), plus \(\Delta t^2C_2\,(e^L-1-L)/L^2=4\times5.5\times0.53732=11.821\), total \(36.329\). The linear rule overestimates \(\mathrm{AUC}_{\text{last}}\) by \(64.200-61.334=2.87\) (4.7 %), nearly all in the long final segment, where the profile falls by a factor of 4.4.
The terminal slope. The windows of the last 3, 4 and 5 points:
| Points | \(\lambda_z\) (1/h) | \(R^2_{\text{adj}}\) | within \(10^{-4}\) of the best? |
|---|---|---|---|
| 3 (8, 12, 24 h) | 0.124476 | 0.99999592 | yes (it is the best) |
| 4 (4–24 h) | 0.124981 | 0.99995825 | yes (difference \(3.8\times10^{-5}\)) |
| 5 (2–24 h) | 0.124160 | 0.99980889 | no (difference \(1.8\times10^{-4}\)) |
Two windows are winners; the rule takes the one with more points, the 4-point window. By hand for it: \(\ln C=(1.7047,\ 1.1939,\ 0.6931,\ -0.7985)\) at \(t=(4,8,12,24)\), so \(\bar t=12\), \(\overline{\ln C}=0.6983\), \(S_{xy}=-27.996\), \(S_{xx}=224\), and
The span of 3.6 half-lives is above the 2 required, and \(R^2_{\text{adj}}\) is far above 0.7: the fit is accepted.
Derived parameters (observed \(C_{\text{last}}=0.45\)):
| Parameter | Value |
|---|---|
| \(C_{\text{last}}/\lambda_z\) | 3.600 |
| \(\mathrm{AUC}_\infty=61.334+3.600\) | 64.935 mg·h/L |
| % extrapolated | 5.54 % |
| \(\mathrm{AUMC}_\infty=457.012+24\times3.600+0.45/0.12498^2\) | 572.234 |
| MRT \(=572.234/64.935\) | 8.81 h |
| CL/F \(=100/64.935\) | 1.540 L/h |
| \(V_z\)/F \(=100/(0.12498\times64.935)\) | 12.32 L |
The extrapolated 5.5 % is well below the 20 % that is a widely used convention (the program's own limit is the max_extrap setting), so \(\mathrm{AUC}_\infty\) would be reported. These numbers are an illustration; the values of the case studies are in Chapter 41 (pages 41.6 onward).
Dose proportionality and group comparison
Power model (Smith et al.). For a parameter \(P\) over doses \(D\):
Perfect proportionality is \(\beta=1\). With dose ratio \(r=D_{\max}/D_{\min}\) and acceptance limits \((\theta_L,\theta_U)=(0.8,\ 1.25)\) the interval of \(\beta\) that is compatible with proportionality is
Illustration: for \(r=4\) (for example 25 to 100 mg), \(\ln0.8/\ln4=-0.161\) and \(\ln1.25/\ln4=+0.161\), so the critical interval is \((0.839,\ 1.161)\). A slope with a 90 % interval inside it is proportional; wholly below, less than proportional; wholly above, greater; otherwise inconclusive. A narrow dose range gives a wider acceptance band (\(\pm0.32\) for \(r=2\), against \(\pm0.16\) for \(r=4\)) but a less precise slope, so the two effects compete.
Geometric-mean ratio. For a test and a reference group, with the differences of the log values \(\bar d\) and standard error \(\mathrm{SE}\) (paired, or Welch for parallel groups):
within 80–125 % if the whole interval is inside the limits. Illustration: \(\bar d=0.0328\), \(\mathrm{SE}=0.04\) and 11 degrees of freedom (\(t_{0.95,11}=1.796\)) give \(\mathrm{GMR}=103.3\,\%\) with a 90 % interval of \(96.2\)–\(111.0\,\%\), inside 80–125 %.
Absolute bioavailability. From an intravenous and an extravascular profile of the same subject, \(F=\dfrac{\mathrm{AUC}_{\text{ev}}/D_{\text{ev}}}{\mathrm{AUC}_{\text{iv}}/D_{\text{iv}}}\), from \(\mathrm{AUC}_{\text{last}}\) and from \(\mathrm{AUC}_{\infty}\).
Common mistakes
- Dropping the "/F" from an extravascular clearance or volume.
- Calling \(\mathrm{AUC}_{\text{last}}\) the \(\mathrm{AUC}_\infty\), or reporting \(\mathrm{AUC}_\infty\) with a large extrapolated fraction without saying so.
- Accepting a \(\lambda_z\) from a window that is shorter than two half-lives.
- Using the linear rule on a steep decline and then comparing with a software that uses the logarithmic rule.
Review checklist
- Can you derive the logarithmic trapezoid and say when it is exact?
- Can you apply the best-fit window rule, including the tolerance and the "most points" tie-break?
- Can you compute \(\mathrm{AUC}_\infty\), MRT, CL/F and \(V_z\)/F from the pieces?
- Can you state the dose-proportionality interval for a given dose ratio?
Navigation
See the previous page, the next page and the mathematical reference.