30.28 Design criteria beyond power
A trial can detect one effect while estimating the rest of the model poorly. nlmx therefore reports convergence, relative bias, RMSE, RSE, coverage, shrinkage, and parameter-specific limits alongside power. A design decision should identify which criteria are required, which are descriptive, and how conflicts are resolved.
Concepts to keep separate
- Relative bias summarises systematic estimation error; RMSE combines bias and variability.
- RSE assesses reported uncertainty relative to an estimate and is judged on the median in SSE to resist explosions from near-zero estimates.
- Coverage asks how often the confidence interval contains replicate truth; nominal 95% coverage is neither guaranteed nor sufficient by itself.
- Shrinkage diagnoses limited individual information, while convergence captures operational estimator reliability.
Terminology matters because a single scenario can contain several denominators and several sources of randomness. Truth is the parameter vector used to generate a replicate. Estimate is the value recovered from that replicate. Design is the planned arrangement of subjects, arms, doses, and observations. Method is the approximation or simulation–estimation procedure used to predict performance. A credible report labels all four.
Mathematical or operational walkthrough
In the Chapter 30 smoke run, N=40 achieved estimated LRT power 0.85 and 100% convergence, yet its scenario-level all_criteria_met value was ‘no’. N=80 was ‘yes’. This is the concrete reason not to design from power alone.
For novices, read every expression from the inside out: identify the scientific effect, identify the null value, put both on the same parameter scale, identify the variance or information that belongs to the actual design, and only then calculate a test statistic or sample size. Units and parameterisation should cancel in a way that leaves a dimensionless statistic.
How this maps to nlmx
Predeclare fixed-effect and random-effect RSE limits, named parameter overrides, bias and shrinkage limits, coverage expectations, and a convergence floor. Review their Monte Carlo precision as carefully as power.
Chapter 30 explains the statistical and implementation concepts. Chapter 31 gives the complete nlmx power command, every CLI and settings control, precedence, output schema, and production workflow. This separation is deliberate: choosing an option correctly requires understanding which estimand and assumption it changes.
Quality-control checklist
- Are critical parameters named?
- Are criteria assessed on appropriate denominators?
- Are near-zero values handled sensibly?
- Does the report distinguish a power pass from an all-criteria pass?
The graph is explanatory; the CSV, JSON, resolved settings, model inputs, and replicate rows are the authoritative evidence. When a plotted point looks surprising, diagnose the underlying rows before changing the design.
Common mistakes
- Reporting only the hypothesis with the best result
- Using mean RSE when extreme near-zero estimates dominate
- Ignoring low coverage because average bias is small
Also avoid copying a sample size from a nearby project. Power is conditional on the model, tested effect, covariate distribution, schedule, residual and random variability, attrition, test, estimator, and success criteria. Similar-looking studies can have very different information.
Evidence to retain
- scientific question, estimand, hypothesis, alpha, target, and criteria;
- model/data/design inputs, parameter source and uncertainty distribution;
- software version, method, approximation, seed, threads, command, and resolved settings;
- scenario grid, row-level results, failures, denominators, intervals, diagnostics, and checksums;
- scripts that calculate derived tables and figures, plus the interpretation and limitations.
Navigation
See the previous page, next page, and formula and decision index.