30.22 Cramér–Rao bound, SE, RSE, and correlation
After assembling F, nlmx inverts it to approximate the estimator covariance. The Cramér–Rao statement is a lower-bound result under regularity conditions; using F-inverse as expected covariance assumes the estimator approaches that bound. SE is the square root of a covariance diagonal. RSE is 100×SE/|parameter value| when that denominator is meaningful.
Concepts to keep separate
- Large off-diagonal covariance produces parameter correlations and can inflate adjusted SEs despite strong individual sensitivities.
- RSE is undefined or unstable near a zero parameter. Use absolute SE or a clinically meaningful scale there.
- A ridge, pseudoinverse, or rank deficiency indicates weak identifiability; it must not be disguised as ordinary precision.
- The largest RSE may belong to a nuisance parameter and still signal a design limitation affecting key estimates.
Terminology matters because a single scenario can contain several denominators and several sources of randomness. Truth is the parameter vector used to generate a replicate. Estimate is the value recovered from that replicate. Design is the planned arrangement of subjects, arms, doses, and observations. Method is the approximation or simulation–estimation procedure used to predict performance. A credible report labels all four.
Mathematical or operational walkthrough
In the reduced executed run at N=40, CL~WT SE was 0.278 and power 0.769. Its effect-scale RSE is about 37.1%. nlmx also reported THETA(5) as the largest parameter RSE at 164.6%, illustrating why power alone is incomplete.
For novices, read every expression from the inside out: identify the scientific effect, identify the null value, put both on the same parameter scale, identify the variance or information that belongs to the actual design, and only then calculate a test statistic or sample size. Units and parameterisation should cancel in a way that leaves a dimensionless statistic.
How this maps to nlmx
Inspect eigenvalues or rank warnings, the covariance/correlation matrix, and parameter-specific limits. A single maximum-RSE label is a prompt for deeper review, not the complete result.
Chapter 30 explains the statistical and implementation concepts. Chapter 31 gives the complete nlmx power command, every CLI and settings control, precedence, output schema, and production workflow. This separation is deliberate: choosing an option correctly requires understanding which estimand and assumption it changes.
Quality-control checklist
- Is inversion stable without material ridge correction?
- Are key correlations reported?
- Are RSE limits appropriate to parameter type?
- Are near-zero parameters assessed on an absolute scale?
The graph is explanatory; the CSV, JSON, resolved settings, model inputs, and replicate rows are the authoritative evidence. When a plotted point looks surprising, diagnose the underlying rows before changing the design.
Common mistakes
- Calling F-inverse an exact sampling covariance
- Using signed parameter values in RSE
- Ignoring singularity because a number was printed
Also avoid copying a sample size from a nearby project. Power is conditional on the model, tested effect, covariate distribution, schedule, residual and random variability, attrition, test, estimator, and success criteria. Similar-looking studies can have very different information.
Evidence to retain
- scientific question, estimand, hypothesis, alpha, target, and criteria;
- model/data/design inputs, parameter source and uncertainty distribution;
- software version, method, approximation, seed, threads, command, and resolved settings;
- scenario grid, row-level results, failures, denominators, intervals, diagnostics, and checksums;
- scripts that calculate derived tables and figures, plus the interpretation and limitations.