Documentation

31.11 Compliance, LLOQ, and BLQ actions

Compliance, LLOQ, and BLQ actions

Compliance removes explicit AMT-positive EVID 1/4 dose records with the stated probability. ADDL-expanded doses are not separate records and are not independently thinned. After simulation, values below numeric LLOQ are dropped, set to half LLOQ, or set to LLOQ.

What the controls mean

  • Compliance is in (0,1]; LLOQ must be positive.
  • CLI --blq-action set-lloq normalises to settings value lloq.
  • FIM ignores compliance and LLOQ; a both run warns that the engines describe different designs.

The issued command is only the beginning of the audit trail. Always distinguish the reference model, the design template, the resolved scenario, the replicate-specific truth, the fitted result, and the test decision. A value can be correct at one layer and misinterpreted at another.

Command or settings pattern

--compliance 0.9 --lloq 0.05 --blq-action half

Command-line values override settings-file values. Use a fresh folder for an analytical run; preserve the command, resolved settings, log, checksums, and row-level data. Defaults are versioned behavior, so a production protocol should state important values explicitly.

Interpretation and quality control

Check dose encoding, realised missed doses, BLQ counts, and whether the proposed clinical likelihood matches substitution or deletion.

For a novice review, first confirm counts and labels, then inspect numerical values, then ask whether the assumptions represent the proposed clinical study. For an expert review, additionally reconcile aggregates from row-level output, reproduce a subset of trials, and compare the implementation with an independent reference where the claim requires it.

Common mistakes

  • Assuming ADDL doses are thinned
  • Entering a column name for power --lloq
  • Reporting a point estimate without its denominator, interval, method, and version

Minimum evidence to retain

  • nlmx version, command, .power file, resolved settings, seed, threads, and output checksums;
  • control stream, design dataset, EXT/COV or parameter sets, and their provenance;
  • scenario table, replicate rows and failures, method summaries, plots, report, and interpretation;
  • prespecified criteria, Monte Carlo target, validation scope, deviations, and reviewer decisions.

See the previous page, next page, and complete command and settings index.