30.21 Reduced versus full Fisher information
The reduced FIM sets dV/dp to zero for parameters that move the mean, retaining the usual mean information while still handling variance parameters. The full FIM includes covariance derivatives for those fixed and covariate effects. In a Gaussian approximation this extra route can produce striking apparent precision, but it may be unavailable to the real nonlinear estimator.
Concepts to keep separate
- Reduced is the nlmx default and the recommended starting point for covariate-effect planning.
- Full can be useful as a diagnostic or theoretical upper-bound-like comparison, not an automatic improvement.
- The executed CL~WT example gave target N=44 with reduced FIM but N=9 with full FIM.
- That more than fourfold difference is a warning: methodological assumptions dominate the nominal sample-size result.
Terminology matters because a single scenario can contain several denominators and several sources of randomness. Truth is the parameter vector used to generate a replicate. Estimate is the value recovered from that replicate. Design is the planned arrangement of subjects, arms, doses, and observations. Method is the approximation or simulation–estimation procedure used to predict performance. A credible report labels all four.
Mathematical or operational walkthrough
At N=20, reduced FIM power was 0.479 with SE 0.393 for the 0.75 effect. Full FIM power was 0.992 with SE 0.172. The added covariance information caused the gap; no extra subjects or observations were present.
For novices, read every expression from the inside out: identify the scientific effect, identify the null value, put both on the same parameter scale, identify the variance or information that belongs to the actual design, and only then calculate a test statistic or sample size. Units and parameterisation should cancel in a way that leaves a dimensionless statistic.
How this maps to nlmx
For the current covariate-effect workflow, use reduced FIM for screening and validate with SSE. If full and reduced are far apart, report both and investigate rather than selecting the smaller N.
Chapter 30 explains the statistical and implementation concepts. Chapter 31 gives the complete nlmx power command, every CLI and settings control, precedence, output schema, and production workflow. This separation is deliberate: choosing an option correctly requires understanding which estimand and assumption it changes.
Quality-control checklist
- Is fim-kind explicit in settings and report?
- How large is the full/reduced precision gap?
- Does SSE align more closely with the reduced result?
- Would the recommendation survive using the conservative method?
The graph is explanatory; the CSV, JSON, resolved settings, model inputs, and replicate rows are the authoritative evidence. When a plotted point looks surprising, diagnose the underlying rows before changing the design.
Common mistakes
- Choosing full because it gives a smaller study
- Averaging full and reduced sample sizes
- Hiding the assumption behind a generic ‘FIM’ label
Also avoid copying a sample size from a nearby project. Power is conditional on the model, tested effect, covariate distribution, schedule, residual and random variability, attrition, test, estimator, and success criteria. Similar-looking studies can have very different information.
Evidence to retain
- scientific question, estimand, hypothesis, alpha, target, and criteria;
- model/data/design inputs, parameter source and uncertainty distribution;
- software version, method, approximation, seed, threads, command, and resolved settings;
- scenario grid, row-level results, failures, denominators, intervals, diagnostics, and checksums;
- scripts that calculate derived tables and figures, plus the interpretation and limitations.
Navigation